ISO8859-1,$-Rq]9!% (6OJq< r I 3   N& \  FG GV,_5oL&b 3F z 3'>6fd[ ^h[oj  X u7 = n7Z+o JE   .4  _!w&!DISPLAY MICROCODE LEVEL %1$s %2$sINSTALL MICROCODE %1$s %2$sdiag [-c] -d -T disp_mcode -c No console mode. Run without user interaction. -d Run the task on the device specified. -T disp_mcode Display the microcode level.diag [-c] -d -T "download [-s {/etc/microcode|diskette}] [-l {latest|previous}] [-f]" -c No console mode. Run without user interaction. -d Run the task on the device specified. -T download Install microcode. -s /etc/microcode Microcode image is in /etc/microcode. Default. -s diskette Microcode image is on diskette. -l latest Install latest level of microcode. Default. -l previous Install previous level of microcode. -f Install microcode even if the current level is not on source.USAGE: diag [-c] -d -T "download [-s /etc/microcode|diskette|] [-l {latest|previous}] [-f]" -c No console mode. Run without user interaction. -d Run the task on the device specified. -T download Download microcode. -s Specify the source for the microcode files. For example: fd0, cd0. /etc/microcode is the default. -l latest Install the latest level of microcode. This is the default. -l previous Install the previous level of microcode. -f Install microcode even if the current level is not on the source. YesNoDVD-ROM DriveSCSI Converter CardPlease run diagnostics on the device to ensure that it is functioning properly.However, an error was detected while unconfiguring the device. Unable to return the device to its original state.Run diagnostics on the DVD-ROM drive to isolate the problem.Run diagnostics on the %1$s drive. If the drive passes diagnostics, the problem may have been caused by the media.UNLOAD...........the media (if any) from the drive.the SCSI Converter Card An error was detected while performing a hard reset on the IDE controller. In order for the microcode installation to take full effect, the operating system must be rebooted. An error was detected while performing a reset. In order for the microcode installation to take full effect, the operating system must be rebooted.DVD-RAM DriveInsufficient memory. malloc() failed. Download of the microcode has completed successfully. The current microcode for %1$s is %2$s. The new microcode will be %3$s. In order for the update to take full effect, the drive must be power-cycled. Until then, it will continue to report and operate at the current level. If power to the drive is supplied via an enclosure that contains other devices, ensure that it is safe to remove power to these devices before power-cycling the enclosure. Download of the microcode has completed successfully. The current microcode for %1$s is %2$s. The new microcode will be %3$s. In order for the update to take full effect, the drive must be power-cycled. Do you wish to manually power-cycle the drive now? Power off the drive. If power to the drive is supplied via an enclosure that contains other devices, ensure that it is safe to remove power to these devices before power-cycling the enclosure. Wait 5 seconds. Restore power to the drive and press Enter./etc/microcodedisketteSelect a device to download the microcode toThe source of the microcode image can either be on the disk in /etc/microcode or on a diskette. Select the source of the microcode image.Insert the microcode diskette in diskette drive %1$s.There is no diskette drive on the system. Please use /etc/microcode as the source for the microcode image file.Microcode installation is in progress.Installation of the microcode has completed successfully. The current microcode for %1$s is %2$s.Installation of the microcode has not completed successfully. The current microcode for %1$s is still %2$s. Please run diagnostics on the device to ensure that it is functioning properly. If the diagnostics on the device completes successfully, contact the service support structure for further assistance.The current microcode for %1$s is %2$s. Available levels to install are listed below. Select the microcode level to be installed. Use Help for explanations of "M", "L", "C" and "P" .%1$c %2$sThe current microcode for %1$s is %2$s.Select a device to have its microcode level displayed.An error was detected while configuring %1$s. Run diagnostics on the device to isolate the problem.The device driver indicates that the device is in use. Free the device and rerun this task.To install microcode, this service aid must have exclusive access to the device %1$s. However, the device driver indicated that the device was in in use. You can free the device or stop installation Use Enter to continue the installation if the device is now free.The microcode image currently installed on the device could not be found on the selected source. Use Enter to continue the installation. Use Cancel to cancel the installation.The device is already at the selected microcode level. Use Enter to continue the installation. Use Cancel to cancel the installation.There was a problem accessing %1$s. Please make sure there is a microcode diskette in %2$s.Could not restore the image from %1$s. Please make sure there is a microcode diskette in backup format in %2$s.No valid microcode image was found in %1$s. Microcode image files for this device have the naming convention %2$s.XXXXXXXX where XXXXXXXX is the revision level of the microcode.There was a problem with the microcode image file. Please make sure that the file is a valid microcode image and is not corrupted. Contact the service support structure for further assistance.A software error occurred. Contact the service support structure for further assistance.Microcode installation is not supported for this device. Please contact the support structure for further assistance.The current microcode level for %1$s could not be determined.The format operation can not be performed on the media in %1$s. Only supported DVD-RAM media can be formatted.The task indicates there is no media in the drive %1$s."M" is the most recent level of microcode found on the source. It is later than the level of microcode currently installed on the device. "L" identifies levels of microcode that are later than the level of microcode currently installed on the device. Multiple later images are listed in descending order. "C" identifies the level of microcode currently installed on the device. "P" identifies levels of microcode that are previous to the level of microcode currently installed on the device. Multiple previous images are listed in the descending order.The current microcode for %1$s is %2$s. The microcode image currently installed on the device could not be found on the selected source. To install microcode, use the -f flag.An error was detected while unconfiguring %1$s. Unable to return the device to its original state. Run diagnostics on the device to isolate the problem.Media is detected in the drive. Please remove the media from the drive and run this task again to update the microcode on the device.The previous level of microcode could not be found on the selected source.A later level of microcode could not be found on the selected source.The task indicates that there is no diskette drive present in the system. /etc/microcode is not available as microcode source in this boot mode. Either add a diskette drive to the system, or boot using disk as boot device and use /etc/microcode as the microcode source.You have chosen to download a previous microcode level. Use Enter to continue the installation. Use Cancel to cancel the installation.An error was detected while initializing the device.Invalid Source: %1$s The selected source is not present or is currently unavailable. Select a different source for the microcode download.To install microcode, this service aid must have exclusive access to the other IDE device %1$s.Insufficient memory. malloc() failed.