ISO8859-1,[cQ@7&    )* &T'{,-A@D0DDTG&vzu a s G V!Z "U #R O$4 % & e'; (L *)/ w*d +? ,tLFailed to configure SEA with return code %d and SEA-specific error code %d: Detailed info: Adapter %s has an interface configured over it, or it belongs to another SEA, VLAN or EtherChannel Adapter %s could not be used because there was not enough memory to configure it Adapter %s could not be used because it does not exist Real adapter %s may not be of type %s Virtual I/O EthernetVLANSEAIVEEtherChannel[Unknown]Virtual adapter %s may not be of type %s No default PVID adapter was specified The name of that SEA is already in use The SEA could not be attached to the system Opening real adapter %s failed with error %d Setting real adapter %s in promiscuous mode failed with error %d Since it is an IVE logical port, it is likely that this VIOS needs to be configured as the IVE physical port's promiscuous logical partition Disabling the address check on real adapter %s failed with error %d Opening virtual adapter %s failed with error %d Setting virtual adapter %s in promiscuous mode failed with error %d Virtual adapter %s is not trunk: it needs to be allowed to access external networks Disabling the address check on virtual adapter %s failed with error %d There is a mismatch between the checksum offload capability between the real adapter and the virtual adapter(s): if the virtual adapter(s) has it enabled, the real adapter must have it enabled as well There is a mismatch in the checksum offload capability within the virtual adapters: they must all either have it enabled, or they must all have it disabled There is a mismatch between the virtual switch names of the the virtual adapters: the virtual switch names must match Retrieving virtual switch information failed with error %d: the system firmware might not be able to support this feature Retrieving virtual adapter information for adapter %s failed with error %d: the system firmware might not be able to support SEA Failover Trunk priority mismatch in virtual adapter %s: all virtual Ethernet adapters must have the same trunk priority value Control channel adapter %s could not be used because there was not enough memory to configure it Control channel adapter %s has an interface configured over it, or it belongs to another SEA, VLAN or EtherChannel Control channel adapter %s could not be used because it does not exist Control channel adapter %s could not be used because it is not a Virtual Ethernet adapter Control channel adapter %s could not be used because it failed to open with error %d Real adapter %s does not support link status notification needed for SEA Failover The GVRP feature failed to initialize with error %d WARNING: The value entered for pvid does not match the pvid of the pvid adapter. Entered value is ignored and correct value is used instead. SEA HA configuration without a control channel adapter is only supported on firmware level 7.8 and above. Please verify firmware level. No detailed error information can be provided for error %d The NDD_SET_LINK_STATUS ioctl failed with return code %d on real adatper %s Adapter %s has an interface configured over it Adapter %s could not be used because it does not exist or it belongs to another SEA or EtherChannel Control channel adapter %s has an interface configured over it Control channel adapter %s could not be used because it does not exist or it belongs to another SEA or EtherChannel