ISO8859-16,01$Vm$ ' * - 1* 3\379:6>q@8<*>g  0108b 8! " #.$2%4O&+'/(1), *# ?+: c,. -3 .5 /6 70: n1 2 3 4 5 6    8 {U 2   r hTk3  Device configuration error.The enclosure failed to open.The enclosure failed to return inquiry data.There is a critical power supply or fan failure.There is a redundant power supply or fan failure.Enclosure Power SupplyEnclosure Fan AssemblyA critical fan failure has occurred.A non-critical fan failure has ocurred.An unrecoverable fan failure has occurred.A critical power supply failure has occurred.A non-critical power supply failure has occurred.An unrecoverable power supply failure has occurred.A critical enclosure services failure has occurred.A non-critical enclosure services failure has occurred.An unrecoverable enclosure services failure has occurred.A critical failure has occurred on a user defined element.A non-critical failure has occurred on a user defined element.An unrecoverable failure has occurred on a user defined element.A critical failure has occurred on an undefined element.A non-critical failure has occurred on an undefined element.An unrecoverable failure has occurred on an undefined element.FanPower SupplyTemperature sensorEnclosure ServicesEnc. ServicesUser defined deviceThere is a critical power supply or fan failure.There is a redundant power supply or fan failure.The enclosure indicates a temperature threshold warning.The enclosure indicates a temperature threshold failure.Repeater CardVPD ModuleA critical repeater card failure has occurred.A non-critical repeater card failure has occurred.An unrecoverable repeater card failure has occurred.A critical vpd module failure has occurred.A non-critical vpd module failure has occurred.An unrecoverable vpd module failure has occurred.A power supply error condition has occurred.A fan error condition has occurred.The enclosure indicates a temperature threshold condition.An expander card error condition has occurred.An enclosure services error condition has occurred.The enclosure indicates a power fault to a media bay.The enclosure indicates a voltage threshold condition.The enclosure indicates a temperature threshold condition.Enclosure Services ControllerVolt. sensorTemp. sensorExpanderMedia BayCableSCSI ENCLOSURE SERVICES DEVICESCSI HOT SWAP ENCLOSURE DEVICE%1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI ENCLOSURE SERVICES DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates one or more disks are powered off. A device may be powered off for the following reasons: -The device was set to the remove state or was powered off. -There is a power problem with the device. -The device is not compatible with the enclosure. RUN......The SCSI Device Identification and Removal Service Aid to determine the state of the device.%1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI ENCLOSURE SERVICES DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates one or more disks are powered off. A device may be powered off for the following reasons: -The device was set to the remove state or was powered off. -There is a power problem with the device. -The device is not compatible with the enclosure. RUN......The Identify and Remove Resource Service Aid to determine the state of the device.%1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI ENCLOSURE SERVICES DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates a device is missing. The device that is missing is: %4$s %5$d Refer to the enclosure service guide for more information. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI ENCLOSURE SERVICES DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates a %4$s failure is being reported from %5$s %6$d Refer to the enclosure service guide for more information. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI ENCLOSURE SERVICES DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates a low temperature threshold warning. Refer to the enclosure service guide for more information. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI ENCLOSURE SERVICES DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates an upper temperature threshold warning. Refer to the enclosure service guide for more information. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI ENCLOSURE SERVICES DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates a low temperature threshold failure. Refer to the enclosure service guide for more information. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI ENCLOSURE SERVICES DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates an upper temperature threshold failure. Refer to the enclosure service guide for more information. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI HOT SWAP ENCLOSURE DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates one or more disks are powered off. A device may be powered off for the following reasons: -The device was set to the remove state or was powered off. -There is a power problem with the device. -The device is not compatible with the enclosure. RUN......The Identify and Remove Resource Service Aid to determine the state of the device.%1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI HOT SWAP ENCLOSURE DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates a %4$s failure is being reported from %5$s %6$d Refer to the enclosure service guide for more information. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI HOT SWAP ENCLOSURE DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates a device is missing. The device that is missing is: %4$s %5$d Refer to the enclosure service guide for more information. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI HOT SWAP ENCLOSURE DEVICE (%2$s) IN LOCATION %3$s The enclosure indicates a required element is not installed. The following element: %4$s must be installed for proper operation. If visual inspection reveals the element is installed, then a fault is making the element undetectable. Contact your service provider. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI HOT SWAP ENCLOSURE DEVICE (%2$s) IN LOCATION %3$s The enclosure controller is reporting an unknown status value for the following element: %4$s The enclosure is reporting a status of %5$d. Verify the latest level of microcode is installed on %6$s. Visually inspect the enclosure for any fault indications. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI HOT SWAP ENCLOSURE DEVICE (%2$s) IN LOCATION %3$s The enclosure controller is reporting an over temperature condition within the enclosure. Verify that: - the room ambient temperature is within the system's operating environment - there is unrestricted air flow around the system - all system covers are closed. If none of these problems exist, contact your service provider. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI HOT SWAP ENCLOSURE DEVICE (%2$s) IN LOCATION %3$s The enclosure controller is reporting a power supply has been turned off. Check Power Supply %4$s. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI HOT SWAP ENCLOSURE DEVICE (%2$s) IN LOCATION %3$s The enclosure controller is reporting a AC power failure. Check the AC power to Power Supply %4$s. %1$06.6lx ADDITIONAL INFORMATION FOR THE SCSI HOT SWAP ENCLOSURE DEVICE (%2$s) IN LOCATION %3$s The resource %1$s is not available for testing because either the resource was moved or the resource failed to configure. Remove the resource using the command: rmdev -l %2$s -d and then run the command: cfgmgr An error will be logged if the resource is present and fails to configure. criticalnon-criticalredundant