ISO8859-1:N*,Jw.% "! &D k 0 /&  #"Dg${@%(A/_@6;#G_ A!4"(#2G$7z%D&Z'` R(\ )J * [+@ v,D -W .2 T/2 0% 1D 2: %36 `4A 5F 6I 7O j8Q 9; :=H;1<A= >@?=\@7A;BC*"DME"kFG*H.I/J65K+lL>M9Nf#xi@V'Loop mode testing will consist of error log analysis only.Temporary device bus error.Device recovered T10 DIF device bus error.Controller recovered T10 DIF host bus error.Temporary controller failure.Controller recovered T10 DIF device bus error.Temporary disk data error.PCI bus error detected by controller.Temporary device bus error.Device detected recoverable error.Storage subsystem configuration error.Disk media format bad.Addressed device failed to respond to selection.Controller detected device bus interface error.Controller timed out a device command.Device bus fabric error.Device T10 DIF device bus error.Controller T10 DIF host bus error.Controller failure.Controller T10 DIF device bus error.Controller detected device error during configuration discovery.Device problem.PCI bus error detected by controller.Disk returned wrong response to adapter.Temporary controller failure.Disk has been modified after last known status.Controller detected device error during internal media recovery.Device bus interface error.Incorrect disk configuration change has been detected.Multiple controllers connected in an invalid configuration.Configuration error, incorrect connection between cascaded enclosures.Configuration error, connections exceed controller design limits.Configuration error, incorrect multipath connection.Unsupported enclosure function detected.Automatic reconstruction initiated for Disk Array.Cache data exists for one or more missing/failed disks.Incompatible disk installed at degraded disk location in Disk Array.Multiple controllers not capable of similar functions or controlling same set of devices.Configuration error, incomplete multipath connection between controller and enclosure detected.Configuration error, incomplete multipath connection between enclosure and device detected.Incomplete multipath connection between controller and remote controller.Missing remote controller.Attached enclosure does not support required multipath function.Background Disk Array parity checking detected and corrected errors.Background Disk Array parity checking detected and corrected errors on specified disk.Disk Array is degraded due to missing/failed disk.Disk Array is degraded due to missing/failed disk.Multipath redundancy level got worse.Controller does not support function expected for one or more disks.Cache data associated with attached disks cannot be found.Cache data belongs to disks other than those attached.Two or more disks are missing from a RAID-5 or RAID-6 Disk Array.One or more Disk Array members are not at required physical locations.Physical location of Disk Array members conflict with another Disk Array.Previously degraded disk in Disk Array not found at required physical location.Disk Array is or would become degraded and parity data is out of synchronization.Maximum number of functional Disk Arrays has been exceeded.Required cache data can not be located for one or more disks.Cache data exists for one or more modified disks.RAID controller resources not available due to previous problems.Disk requires Format before use.Maximum number of functional Disk Array disks has been exceeded.One or more disk pairs are missing from a RAID-10 Disk Array.One or more disks are missing from a RAID-0 Disk Array.Maximum number of functional Disk Arrays has been exceeded.Controller failure.Controller device bus configuration error.Permanent controller failure.Temporary device bus fabric error.Adapter configuration error.Device Bus fabric performance degradation.Configuration error, cable VPD cannot be read.Configuration error, required cable is missing.Configuration error, invalid cable Vital Product Data.Thermal error, controller exceeded maximum.Please contact your next level of support or service provider.Reallocation failed due to disk out of alternate sectors.One or more disk pairs are missing from a RAID-10 Disk Array or missing tier from a tiered Disk Array.%1$06.6lx ADDITIONAL INFOR0MATION FOR %2$s IN LOCATION %3$s No trouble was found. However, resource %4$s could not be restored to its initial defined state. If you do not want the device to remain in the available state, run the following command from the command line: rmdev -l %5$s -Rd%1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s An adapter configuration error has been detected. This may indicate an invalid configuration. Check and verify correct controller configuration.%1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s Analysis of the error log indicates a microcode problem. Download the latest microcode available to the controller. If the problem persists, contact your local service support.%1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s Error Log Analysis indicates a client partition attempted unsupported VSCSI Block Header Packing. Validate adapter capabilities and adapter microcode level for support of VSCSI Block Header Packing. If the problem persists contact your local service support. %1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s Error Log Analysis indicates the number of devices attached to the adapter is more than what is specified in the ODM. Increase the max_devices ODM parameter for the adapter. If the problem persists contact your local service support.