ISO8859-1 04r7i  [3* ^ R$ :"Ehz   "   >  S i$ ) * * ! -$ O) t* * !   * F a y   ! " # $  & 5 Q \ j t         ," J# m#   " ##5Yt)m8tB46 Y!"d#&&|'):YESNOThe following test requires a wrap plug with one of the following Part Numbers: %1$s. Do you have this wrap plug?* * * CAUTION * * * CAUTION * * * CAUTION * * * Looking into a fibre optic cable can damage your eyes. UNPLUG.........the system cable, if attached, from the connector on the adapter. PLUG...........the wrap plug into the connector on the adapter. Use a wrap plug with one of the following Part Numbers: %1$s.UNPLUG.........the wrap plug from the connector on the adapter. PLUG...........the system cable, if removed, into the connector on the adapter.* * * NOTICE * * * NOTICE * * * NOTICE * * * Wrap tests are not executed during loop mode.Closing the adapter may require up to %1$s minutes.No trouble found. However, the resource was not completely tested because the SR-IOV logical port interface assigned to this partition indicated that the resource was not available for diagnostic mode. The resource not completely tested is: %1$s To completely test this resource: At the management console, enable diagnostic mode for the SR-IOV logical port assigned to this partition.Module Information Expected Speed:..... %1$d Gbps Current Speed:...... %2$d Gbps EEH error.Configuration Register Test error.Reset Test error.Register Test error.SRAM Test error.Interrupt Test error.PCI Loopback Test error.Internal Loopback Test error.External Loopback Test error.DMA Test error.Configuration Register Test error.DMA Read Test error.DMA Write Test error.DMA Read and Write Test error.Normal Internal Loopback Test error.IP Checksum Internal Loopback Test error.TCP Checksum Internal Loopback Test error.UDP Checksum Internal Loopback Test error.TSO Internal Loopback Test error.Normal External Loopback Test error.IP Checksum External Loopback Test error.TCP Checksum External Loopback Test error.UDP Checksum External Loopback Test error.TSO External Loopback Test error.TU read/write errorAdapter configuration errorPermanent adapter failure.Adapter taken off-line.Adapter parity error.Adapter down error.EEPROM Read Error.Ethernet hardware error.Ethernet configuration error.Ethernet EEH error.Port Link failedPort Speed mismatchOpening deviceConfiguration Register TestReset TestRegister TestSRAM TestInterrupt TestPCI Loopback TestInternal Loopback TestExternal Loopback TestDMA TestClosing deviceConfiguration Register TestDMA Read TestDMA Write TestDMA Read and Write TestNormal Internal Loopback TestIP Checksum Internal Loopback TestTCP Checksum Internal Loopback TestUDP Checksum Internal Loopback TestTSO Internal Loopback TestNormal External Loopback TestIP Checksum External Loopback TestTCP Checksum External Loopback TestUDP Checksum External Loopback TestTSO External Loopback Test%1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s No trouble was found. However, the resource was not tested because other adapter ports are configured. To test this resource, you can perform one of the following: 1) Unconfigure the other ports and run Diagnostics again. 2) Shut down the system and run in maintenance mode. 3) Run Diagnostics from the Diagnostic Standalone package. %1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s The adapter has detected that the link between the adapter and the switch is down and could not successfully recover the link. Check that the switch module is powered on and is properly seated.%1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s No trouble has been found with this adapter. However, Error Log Analysis indicates that there may recently have been a network problem. Check for extensive network traffic and that the switch module is powered on and is properly seated.%1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s No trouble has been found with this adapter. However, Error Log Analysis indicates that there may recently have been a network problem. If your Ethernet adapter is connected to a network and if you are experiencing problems with network communications, check for a loose or defective cable or connection.%1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s No trouble has been found with this adapter. However, Error Log Analysis indicates that there may recently have been a network problem. If your Ethernet adapter is connected to a network and if you are experiencing problems with network communications, check for a loose or defective cable or connection. If this is not the cause, and if you are still experiencing problems, run advanced diagnostics.%1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s Error Log Analysis has detected multiple communication errors. These errors can be caused by a switch or hub. If connected to a switch, refer to the Storage Area Network (SAN) problem determination procedures for additional problem resolution. If not connected to a switch, refer to the hub documentation for problem resolution. %1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s Error Log analysis has detected multiple link errors. These errors can be caused by loose or defective cables. Check all cables and their connections. %1$06.6lx ADDITIONAL INFORMATION FOR %2$s IN LOCATION %3$s Error Log Analysis indicates a possible problem with the adapter microcode. Make sure that the latest level of microcode is installed on the adapter. If the microcode is at the latest level and the problem persists, contact your service support structure. INSTALL MICROCODE %1$s %2$s Installation of the microcode has not completed successfully. A software error occurred. Contact the service support structure for futher assistance. Installation of the microcode has not completed successfully. The current microcode level for %1$s is still %2$s. A software error occurred. Contact the service support structure for futher assistance. Installation of the microcode has not completed successfully. A hardware error occurred. Contact the service support structure for futher assistance. Installation of the microcode has not completed successfully. The current microcode level for %1$s is still %2$s. A hardware error occurred. Contact the service support structure for futher assistance. Installation of the microcode has not completed successfully. An error was detected while configuring the following resources %2$s Please run diagnostics on all of the following resources to ensure that the adapter is functioning properly %1$s Installation of the microcode has completed successfully on the following instances of the adapter: %1$s The current microcode level is %2$s. Please run diagnostics on these resources to ensure that the adapter is functioning properly Installation of the microcode has completed successfully on the following instances of the adapter: %1$s The current microcode level is %2$s. However, an error was detected while restoring one or more of the resources to its initial state. An error was detected for the following resources %3$s. Please run diagnostics on all of the following resources to ensure that the adapter is functioning properly %1$s Installation of the microcode has completed successfully on the following instances of the adapter: %1$s The current microcode level is %2$s. However, the Configuration Data Base was not properly updated for the following resources %3$s. To properly update the Configuration Data Base, please run: rmdev -l resource -R (for each resource listed) followed by: cfgmgr -l resource (for each resource listed) Until this is done, neither lscfg nor the Display Microcode Task will reflect the correct microcode information. A software error occurred. Contact the service support structure for further assistance. **NOTICE *** NOTICE ** This adapter contains multiple ports that share a common microcode image. The common resources presently found are: %1$s When a microcode update is performed on the selected resource, the common resources are also updated. It is recommended that microcode installation be scheduled during non-peak production periods. If any drives are attached to this adapter, make sure that a current backup is available **NOTICE *** NOTICE ** This adapter contains multiple ports that share a common microcode image. The common resources presently found are: %1$s When a microcode update is performed on the selected resource, the common resources are also updated. Some of the resources of the adapter are currently not defined in the system. When these resources are configured, they will also have the newly installed microcode. It is recommended that microcode installation be scheduled during non-peak production periods. If any drives are attached to this adapter, make sure that a current backup is available This adapter contains multiple ports that share a common microcode image. The common resources presently found are: %1$s To update microcode on this adapter, microcode needs to be installed via an available fibre channel port. There are no fibre channel ports available to perform the download operation at this time. Please make sure that a fibre channel port is configured and run this task again This adapter contains multiple ports that share a common microcode image. The common resources presently found are: %1$s When a microcode update is performed on the selected resource, the common resources are also updated. The following resources are not in the proper state for the download operation %2$s Free these resources and attempt microcode installation again The system configuration indicates that there are client processes using this adapter. Microcode Download can not proceed under these circumstances.